Brineura Drug Information
Generic name: CERLIPONASE ALFA
Uses of Brineura
is indicated to slow the loss of ambulation in pediatric patients with neuronal ceroid lipofuscinosis type 2 (CLN2 disease), also known as tripeptidyl peptidase 1 (TPP1) deficiency. BRINEURA is a hydrolytic lysosomal N-terminal tripeptidyl peptidase indicated to slow the loss of ambulation in pediatric patients with neuronal ceroid lipofuscinosis type 2 (CLN2 disease), also known as tripeptidyl peptidase 1 (TPP1) deficiency.
Dosage & Administration of Brineura
| 100 mg | |
| 150 mg | |
| 200 mg (first 4 doses) | |
| 300 mg (subsequent doses) | |
| 300 mg |
Side Effects of Brineura
Clinical Trials Experience
Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. Trial 1 and Trial 2 The safety of BRINEURA was evaluated in 24 patients with CLN2 disease who received at least one 300 mg dose of BRINEURA given by intraventricular infusion in a clinical trial with extension (Trials 1 and 2) of up to 161 weeks . Table 2 summarizes the most common adverse reactions that occurred in BRINEURA-treated patients through 96 weeks. Table 2: Adverse Reactions Reported in ≥ 8% of Symptomatic Pediatric Patients with CLN2 Disease in BRINEURA Trial 1 and Trial 2 at Week 96 Adverse Reaction Patients Treated with BRINEURA n=24 (%) Increased body temperature Increased body temperature includes: increased body temperature and pyrexia 17 ECG abnormalities ECG abnormalities include: non-specific repolarization abnormality, notched QRS, ST segment elevation, biphasic T wave abnormality, supraventricular extrasystoles, bradycardia, sinus tachycardia, and intraventricular conduction delay 17 Decreased CSF protein 17 Vomiting 15 Seizures Seizures include: atonic, generalized tonic-clonic, focal, and absence 12 Device-related complications Device-related complications include device-related infection, delivery system-related complications (needle issues, device leakage, device malfunction, device difficult to use, medical device site irritation, device breakage, etc.) and pleocytosis. 12 Hypersensitivity Hypersensitivity includes only hypersensitivity 9 Increased CSF protein 5 Hematoma 5 Headache 4 Irritability 4 Pleocytosis 4 Device-related infections Device-related infections include: Propionibacterium acnes and Staphylococcus epidermidis 2 Bradycardia 2 Feeling jittery 2 Hypotension 2 Description of Selected Adverse Reactions from Trial 1 and Trial 2 at 96 weeks Seizures Seizures were reported in 12 of 24 (50%) patients.
The seizure types reported include atonic, generalized tonic-clonic, focal, and absence. Seizures were managed with standard anti-convulsive therapies and did not result in discontinuation of BRINEURA treatment. Device-Related Complications Adverse reactions related to the device were observed in 12 of 24 (50%) of patients.
Device-related adverse reactions include infection, delivery system-related complications, and pleocytosis. Nine out of 24 patients (38%) experienced adverse reactions, which involved complications of the non-implanted delivery system components. Four out of 24 patients (16%) had device-related adverse reactions, which required medical intervention, including two patients (8%) with intraventricular access device-related CNS infections, and one patient (4%) each with leakage of the intraventricular access device and pleocytosis.
Device-related infections were diagnosed by increased CSF pleocytosis and microbiology culture and organism identification, without accompanying signs and symptoms of meningitis. Intraventricular access devices were replaced and infections were treated with antibiotics. Device-related complications did not result in discontinuation of BRINEURA treatment.
Hematoma Hematoma adverse reactions were reported in 5 of 24 (21%) patients treated with BRINEURA and presented as hematoma, post procedural hematoma, traumatic hematoma and subdural hematoma. Hematomas did not require treatment and did not interfere with BRINEURA infusion. Hypersensitivity Hypersensitivity reactions were reported in 11 out of 24 patients (46%) treated with BRINEURA during or within 24 hours after completion of the BRINEURA infusion, despite pre-medication with antihistamines with or without antipyretics or corticosteroids.
The most common manifestations observed concomitantly with hypersensitivity included pyrexia with vomiting, pleocytosis, or irritability, which are not consistent with classic immune mediated hypersensitivity. Symptoms resolved over time or with administration of antipyretics, antihistamines and/or corticosteroids and no patient discontinued treatment with BRINEURA. One patient experienced hypoxia (decreased oxygen saturation less than 88% by pulse oximeter), 8 hours after BRINEURA infusion, followed by a low mean arterial pressure at 15 hours post infusion. Symptoms resolved after oxygen administration, airway repositioning and normal saline infusion.
One patient reported decreased oxygen saturation (90% by pulse oximeter), 45 minutes after starting BRINEURA with associated low diastolic blood pressures. Hypoxia resolved after oxygen administration. No treatment was administered for the low diastolic blood pressure, which returned to normal while the patient continued to receive BRINEURA infusion without change to the infusion rate or dose.
Trial 3 Trial 3 enrolled 14 patients aged 1 to 6 years at baseline who received BRINEURA at the recommended dose based on the age of the patient, every other week for a median of 142 weeks. Adverse reactions that occurred in at least 5% of patients are described in Table 3. The most frequent adverse reactions reported in patients < 3 years treated with BRINEURA were similar to those observed in patients ≥ 3 years of age except for hypersensitivity reactions, which were reported in 5 of 8 (63%) in patients < 3 years at baseline compared with 0 of 6 in patients ≥ 3 years of age at baseline. The most common manifestations of hypersensitivity were pyrexia and vomiting and the timing and resolution were similar to Trials 1 and 2. Symptoms of severe hypersensitivity reactions (e.g., anaphylaxis) included tachycardia, bronchospasm, rash, diarrhea, hypotension, increased body temperature and vomiting.
Drug-related IARs In Trial 3, 12 patients (86%) who received BRINEURA had 83 IARs. Of those, 8 patients were < 3 years of age and 4 were ≥ 3 years of age. The symptoms occurring in more than one patient consisted of vomiting, seizure, rash, pyrexia, hypersensitivity, and abnormal electrocardiogram.
Eight (57%) patients had serious IARs: pyrexia, hypersensitivity, anaphylactic reaction, seizure, and pleocytosis. Device-related IARs In Trial 3, 3 patients (21%) who received BRINEURA had 3 IARs related to the intraventricular device. Of those, 2 were < 3 years of age and 1 was ≥ 3 years of age.
The events were: device leakage, device breakage, and CSF red blood cell count positive. One (7%) patient had a serious IAR of device leakage. Table 3: Adverse Reactions Reported in ≥ 5% of Pediatric Patients (1 to 6 years of age) with CLN2 Disease treated with BRINEURA in Trial 3 Adverse Reaction Age 1 to 3 years n=8 (%) Age 3 to 6 years n=6 (%) Total n=14 (%) Note: Incidence numbers are based on baseline age group ECG abnormalities ECG abnormalities include: non-specific repolarization abnormality, supraventricular extrasystoles, possible left ventricular hypertrophy, intermittent 2 nd degree AV Block (type 2 Mobitz), incomplete right bundle branch block, and prominent Q wave. 8 6 14 Decreased CSF protein 8 4 12 Increased body temperature Increased body temperature includes: increased body temperature and pyrexia. 6 6 12 Seizures Seizures include: atonic, febrile convulsion, generalized tonic-clonic, partial, partial with secondary generalization, petit mal epilepsy, myoclonic and status epilepticus. 4 4 8 Device-related complications Device-related complications include device-related infection, delivery system-related complications (needle issues, device leakage, device malfunction, device difficult to use, medical device site irritation, device breakage, etc.) 3 2 5 Vomiting 2 3 5 Hypersensitivity Hypersensitivity includes only the term of hypersensitivity 4 0 4 Hematoma 2 0 2 Increased CSF protein 1 0 1 Pleocytosis 1 0 1 Irritability 0 1 1 Headache 1 0 1
Postmarketing Experience
The following adverse reactions have been identified during post-approval use of BRINEURA. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. Immune system disorders : Anaphylactic reaction characterized by acute pyrexia, respiratory distress (bronchospasm, hypoxemia, perioral cyanosis), tachycardia, hypotension, diarrhea, and rash . Infections and infestations : Bacterial meningitis .
Warnings & Cautions for Brineura
Hypersensitivity Reactions Including Anaphylaxis Life-threatening hypersensitivity reactions including anaphylaxis have been reported
in patients treated with enzyme replacement therapies, including BRINEURA. BRINEURA-treated patients have had these reactions occur in clinical studies and postmarketing use . In clinical Trial 1 and Trial 2 to 96 weeks, a total of 11 of 24 (46%) patients experienced hypersensitivity reactions during the infusion or within 24 hours of completion of the infusion. Patients in clinical trials were routinely pre-medicated with antihistamines with or without antipyretics or corticosteroids, prior to infusion of BRINEURA. During postmarketing use, anaphylactic reactions occurred during or within several hours of BRINEURA infusion. Epinephrine was administered in these patients, and they received subsequent BRINEURA infusions without recurrence of anaphylaxis.
In Trial 3, hypersensitivity reactions were reported in 5 of 8 (63 %) patients less than 3 years of age at baseline as compared to 0 of 6 patients ≥ 3 years of age at baseline . Of the reported hypersensitivity reactions, a single anaphylactic reaction occurred in a subject < 3 years of age. Anaphylaxis has occurred during the early course of enzyme replacement therapy and after extended duration of therapy. Administration of BRINEURA should be supervised by a healthcare provider knowledgeable in the management of hypersensitivity reactions including anaphylaxis.
Initiate BRINERUA in a healthcare setting with appropriate medical monitoring and support measures, including access to cardiopulmonary resuscitation equipment. Premedication of patients with antihistamines with or without antipyretics or corticosteroids is recommended 30 to 60 minutes prior to the start of infusion. Observe patients closely during and after the infusion.
If a severe hypersensitivity reaction (e.g., anaphylaxis) occurs, discontinue BRINEURA and immediately initiate appropriate medical treatment including use of epinephrine. Inform patients and caregivers of the symptoms of life-threatening hypersensitivity reactions, including anaphylaxis and to seek immediate medical care should symptoms occur. The management of hypersensitivity reactions should be based on the severity of the reaction and may include temporarily interrupting the infusion, and/or treatment with antihistamines, antipyretics, and/or corticosteroids.
Consider the risks and benefits of readministration of BRINEURA following an anaphylactic reaction. If the decision is made to readminister BRINEURA after the occurrence of anaphylaxis, ensure appropriately trained personnel and equipment for emergency resuscitation (including epinephrine and other emergency medicines) are readily available during infusion. Initiate subsequent infusion at approximately one-half the initial infusion rate at which the anaphylactic reaction occurred.
Meningitis and Other Intraventricular Access Device-Related Infections Bacterial meningitis requiring antibiotic treatment
and removal of the device was reported during postmarketing use of BRINEURA. Additionally, in clinical trials and during postmarketing use there were reports of other device-related clinical infections which were confirmed by positive CSF cultures, treated with antibiotics and removal of the entire intraventricular access device, and in which patients resumed treatment with BRINEURA after the device was replaced . In all cases, antibiotics were administered, the intraventricular access devices were removed and replaced, and patients resumed treatment with BRINEURA. The signs and symptoms of infections may not be readily apparent in patients with CLN2 disease. To reduce the risk of infectious complications, BRINEURA should be administered by, or under the supervision of, a physician experienced in intraventricular administration. Prior to each infusion of BRINEURA and when clinically indicated, obtain a sample of CSF for cell count and culture.
Do not administer BRINEURA if there are localized signs of infection on or around the device insertion site, such as erythema, tenderness, or discharge or suspected or confirmed CNS infection (e.g., cloudy CSF or positive CSF gram stain, or meningitis) . Healthcare providers should be vigilant for the development of signs and symptoms of infection, including meningitis, during treatment with BRINEURA and monitor the device insertion site for signs of infection.
Intraventricular Access Device-Related Complications During the clinical trials and in postmarketing reports
intraventricular access device-related complications were reported (e.g., device leakage, device failure extravasation of CSF fluid, or bulging of the scalp around or above the intraventricular access device) . For any complications with the implanted intraventricular access device, consult with a neurosurgeon to confirm the integrity or performance of the device. In case of intraventricular access device-related complications, discontinue the BRINEURA infusion and refer to the device manufacturer's labeling for further instructions . Material degradation of the intraventricular access device reservoir was reported after approximately 4 years of administration, which may impact the effective and safe use of the device. During benchtop testing such material degradation was recognized after approximately 105 perforations of the intraventricular access device.
The intraventricular access device should be replaced prior to 4 years of single-puncture administrations, which equates to approximately 105 administrations of BRINEURA.
Cardiovascular Adverse Reactions
Monitor vital signs (blood pressure, heart rate) before infusion starts, periodically during infusion, and post-infusion in a healthcare setting . Upon completion of the infusion, clinically assess the patient status. Continued observation may be necessary if clinically indicated. Perform electrocardiogram (ECG) monitoring during infusion in patients with a history of bradycardia, conduction disorder, or with structural heart disease, as some patients with CLN2 disease may develop conduction disorders or heart disease.
In patients without cardiac abnormalities, regular 12-lead ECG evaluations should be performed every 6 months. In clinical Trial 1 and Trial 2 to 96 weeks, hypotension was reported in 2 of 24 (8%) patients, which occurred during or up to eight hours after BRINEURA infusion. Patients did not require alteration in treatment, and reactions resolved spontaneously or after intravenous fluid administration .
Infusion-Associated Reactions Infusion-associated reactions (IARs) such as vomiting, seizure, rash, pyrexia, hypersensitivity
and anaphylactic reaction have been observed in patients treated with BRINEURA . Premedication of patients with antihistamines with or without antipyretics or corticosteroids is recommended 30 to 60 minutes prior to the start of infusion. If an IAR occurs, decreasing the infusion rate, temporarily stopping the infusion, and/or administering antihistamines and/or antipyretics may ameliorate the symptoms. Closely monitor patients who have experienced IARs when re-administering BRINEURA. In Trial 3, infusion-associated reactions were reported in 8 of 8 patients less than 3 years of age at baseline as compared to 4 of 6 patients ≥ 3 years of age at baseline.
Pregnancy Safety for Brineura
Pregnancy Risk Summary There are no available data on BRINEURA use in pregnant women to inform a drug-associated risk of pregnancy-related outcomes. Animal reproduction studies have not been conducted using cerliponase alfa. The estimated background risk of major birth defects and miscarriage for the indicated population is unknown.
All pregnancies have a background risk of birth defect, loss, or other adverse outcomes. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2 to 4% and 15 to 20%, respectively.
Pediatric Use of Brineura
Pediatric Use The safety and effectiveness of BRINEURA have been established to slow the loss of ambulation in pediatric patients with CLN2 disease and the information on this use is discussed throughout the labeling. BRINEURA is not recommended for use in patients less than 37 weeks post-menstrual age (gestational age at birth plus post-natal age) or those weighing less than 2.5 kg due to physiologic immaturity which may increase risk of serious and clinically significant adverse reactions observed with BRINEURA . Patients less than 3 years of age may be at increased risk for developing hypersensitivity reactions with BRINEURA use compared to patients 3 years of age and older.
Contraindications for Brineura
is contraindicated in patients with: any sign or symptom of acute, unresolved localized infection on or around the device insertion site (e.g., cellulitis or abscess); or suspected or confirmed CNS infection (e.g., cloudy CSF or positive CSF gram stain, or meningitis) . any acute intraventricular access device-related complication (e.g., leakage, extravasation of fluid, or device failure). ventriculoperitoneal shunts. Any sign or symptom of acute or unresolved localized infection on or around the device insertion site (e.g. cellulitis or abscess); or suspected or confirmed CNS infection (e.g., cloudy CSF or positive CSF gram stain, or meningitis). Any acute intraventricular access device-related complication (e.g., leakage, extravasation of fluid, or device failure). Patients with ventriculoperitoneal shunts.
Clinical Studies of Brineura
Follow-up through Week 96 6 16 59% 11 Trial 3 (NCT02678689) was
a Phase 2, open label clinical study designed to enroll symptomatic and presymptomatic CLN2 patients less than 18 years of age. The trial enrolled 14 patients ranging in age from 1 to 6 years at baseline, including 8 patients less than 3 years of age, the median age was 2.7 years. Patients received BRINEURA at the recommended dose every 2 weeks by intraventricular infusion for 144 weeks (1 patient withdrew to receive treatment commercially). Fifty-seven percent of patients were female and 43% were male.
All patients were White; for ethnicity, 14% identified as Hispanic/Latino, 86% as non-Hispanic/Latino. The mean baseline CLN2 Motor score was 2.3 (standard deviation (SD) 0.83) with a range from 1 to 3. Thirteen of the 14 BRINEURA treated patients were matched with up to 3 natural history comparators on the basis of age within 3 months, equal CLN2 Motor score, and genotype (0, 1, or 2 key mutations). None of the BRINEURA treated patients (N=14) had a 2-point decline or score of zero in the Motor scale by Week 169. Among the matched natural history comparators (N=31), 20 subjects (65%) had an unreversed 2-point decline or score of zero by last assessment. The median time to an unreversed 2-point decline in Motor score or score of 0 was 133 weeks among the natural history comparators and was not reached by last assessment (Week 169) in patients treated with BRINEURA. In patients below 3 years of age, none (0%) of the BRINEURA treated patients (N=8) had a 2-point decline or score of zero in the Motor score by Week 169. Among the 8 treated patients, 7 were matched to 18 untreated patients from the natural history cohort.
Among the matched natural history comparators (N=18), 11 subjects (61%) had an unreversed 2-point decline or score of zero in the Motor score by last assessment. All seven of the treated patients below 3 years of age with a motor score of 3 at baseline remained at a motor score of 3 at the last measured timepoint, which represents grossly normal gait. In this population BRINEURA treated patients showed a delay in disease onset.